Sign In | Join Free | My wneducation.com
China CITEST DIAGNOSTICS INC. logo
CITEST DIAGNOSTICS INC.
CITEST DIAGNOSTICS INC.
Verified Supplier

3 Years

Home > Cardiac Marker Test Kit >

CE 500ng/ML D Dimer Rapid Test Kit DIC DVT PE Cardiac Marker Test Kit

CITEST DIAGNOSTICS INC.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

CE 500ng/ML D Dimer Rapid Test Kit DIC DVT PE Cardiac Marker Test Kit

  • 1
  • 2
  • 3

Brand Name : Citest

Model Number : CDM-402

Certification : CE

Place of Origin : -

MOQ : N/A

Price : negotiation

Supply Ability : 10 M tests/month

Delivery Time : 2-4 Weeks

Packaging Details : 10 T

Product : D - Dimer Rapid Test Kit , Rapid Diagnostic Test CE ,Cardiac Marker Test Kit

Cat No. : CDM-402

Principle : Chromatographic Immunoassay

Format : Cassette

Specimen : WB / P

Certificate : CE

Reading Time : 10 minutes

Pack : 10 T

Storage Temperature : 2-30°C

Shelf Life : 2 Years

Sensitivity : 97.2%

Specificity : 94.0%

Accuracy : 96.4%

Cut-Off : 500 ng/mL

Contact Now

D-dimer Rapid Test Cassette with High Precise / Accurate

Product features Parameters
Principle Chromatographic Immunoassay
Format Cassette
Specimen WB / P
Certificate CE
Reading Time 10 minutes
Pack 10 T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity 97.20%
Specificity 94.00%
Accuracy 96.40%
Cut-Off 500 ng/mL

Applications:

The D-dimer Rapid Test Cassette (Whole Blood/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of human D-dimer in whole blood or plasma as an aid in the diagnosis of Disseminated Intravascular Coagulopathy (DIC), deep venous thrombosis (DVT) and pulmonary embolism (PE).

Description:

D-dimer (or D dimer) is a fibrin degradation product (or FDP), a small protein fragment present in the blood after a blood clot is degraded by fibrinolysis. It is so named because it contains two cross linked D fragments of the fibrin protein. D-dimer concentration may be determined by a blood test to help diagnose thrombosis.
Since its introduction in the 1990s, it has become an important test performed in patients with suspected thrombotic disorders. While a negative result practically rules out thrombosis, a positive result can indicate thrombosis but does not rule out other potential causes. Its main use, therefore, is to exclude thromboembolic disease where the probability is low. In addition, it is used in the diagnosis of the disorder Disseminated Intravascular Coagulopathy.
The D-dimer Rapid Test Cassette (Whole Blood/Plasma) is a simple test that utilizes a combination of anti-D-dimer antibody coated particles and capture reagents to qualitatively detect D-dimer in whole blood or plasma. The minimum detection level is 500ng/mL.

CE 500ng/ML D Dimer Rapid Test Kit DIC DVT PE Cardiac Marker Test Kit

How to use?

Allow the test, specimen, buffer and/or controls to reach room temperature (15-30 °C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Place the cassette on a clean and level surface.
For Plasma specimen:
· Hold the dropper vertically and transfer 1 drop of plasma (approximately 25µL) to the specimen area, then add 2 drops of buffer (approximately 80µL), and start the timer. See illustration below.
For Venipuncture Whole Blood specimen:
· Hold the dropper vertically and transfer 1 drop of whole blood (approximately 25µL) to the specimen area, then add 2 drops of buffer (approximately 80µL), and start the timer.
See illustration below.
For Fingerstick Whole Blood specimen:
· To use a capillary tube: Fill the capillary tube and transfer approximately 25µL of fingerstick whole blood specimen to the specimen area of test cassette, then add 2 drops of buffer (approximately 80µL) and start the timer. See illustration below.

3. Wait for the colored line(s) to appear. Read result at 10 minutes. Do not interpret the result after 20 minutes.
Note: It is suggested not to use the buffer, beyond 6 months after opening the vial.

CE 500ng/ML D Dimer Rapid Test Kit DIC DVT PE Cardiac Marker Test Kit

INTERPRETATION OF RESULTS
(Please refer to the illustration above)
POSITIVE:* A colored line in the control line region (C) and the presence of one colored line in the test line region indicate a positive result. This indicates that the concentration of D-dimer is above the minimum detection level.
*NOTE: The intensity of the color in the test line region will vary depending on the concentration of D-dimer, present in the specimen. Therefore, any shade of color in the test line region should be considered positive.
NEGATIVE: One colored line appears in the control line region (C). No line appears in the test line region (T).This indicates that the concentration of D-dimer are below the minimum detection levels.
INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.
Order Information
Cat. No. Product Specimen Pack
CDM-402 D-dimer Rapid Test WB/S/P 10T

Product Tags:

CE 500ng/ML D Dimer Rapid Test Kit

      

DIC DVT D Dimer Rapid Test Kit

      

DVT PE Cardiac Marker Test Kit

      
Buy cheap CE 500ng/ML D Dimer Rapid Test Kit DIC DVT PE Cardiac Marker Test Kit product

CE 500ng/ML D Dimer Rapid Test Kit DIC DVT PE Cardiac Marker Test Kit Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: CITEST DIAGNOSTICS INC.
*Subject:
*Message:
Characters Remaining: (0/3000)